Monday, August 5, 2013

Three-phase series small wind turbine grid-connected inverter

Three-phase series small wind turbine grid-connected inverter
 
1.Using IGBT from Mitsubishi company as the power components
2.Using American ATEMEL company microprocessor as figure controller
3.Perfect protection and warning functions
4.Wind turbine MPPT technology, real-time tracing wind turbine max. output power
5.Disturbance detection technology, anti-island control
6..Circuit frame compact, Max. Efficiency≥94%
7.Outdoor stainless steel shell, fully sealed installation
8.With RS485/RS232, Ethernet, GPRS (optional) interfaces, remote data collection and surveillance
9.Pure sine wave output, automatic synchronization grid connected, non-polluting to the power grid, no impact
10..Inverting current close-cycle control,power to control and adjustable
11..Big-screen English LCD, perfect display, interface-friendly
Three-phase series small wind turbine grid-connected inverter
Technical data: 
 
Model
BNWG-10KS
BNWG-30KS
BNWG-50KS
BNWG-100KS
BNWG-250KS
BNWG-500KS
Rating capacity
10 KVA
30 KVA
50 KVA
100 KVA
250 KVA
500 KVA
Rating AC output power
10 KVA
30 KVA
50 KVA
100 KVA
250 KVA
500 KVA
Max. AC output power
12 KVA
36 KVA
60 KVA
120 KVA
300 KVA
600 KVA
Isolation
Low frequency transformer isolation
Recommending wind turbine power
12 KVA
36 KVA
60 KVA
120KVA
300 KVA
600 KVA
Max.AC open circuit voltage
780VDC
780VDC
780VDC
780VDC
1150VDC
1150VDC
MPPT range
200~780VDC
200~780VDC
400~780VDC
400~780VDC
400~1150VDC
400~1150VDC
Max. DC Input current
50A
150A
125A
250A
625A
1250A
DC connecting mode
Connecting terminal
Max. Efficiency
94%
Euro efficiency
92%
Allowing network voltage range(three phase)
320~440VAC
Allowing network frequency range
50HZ±2%&60HZ±2%
Total current waveform distortion factor
<3%
Power factor
≥0.99
Internal power consumption an night
<10W
Comm. interfaces
RS485/RS232
electrical insulating performance
1500Vac,1minute
Using environment temperature
-25~+60℃
Using environment humidity
0~100%
Protection
Input short voltage、over voltage、opposing connection,output over current、short circuit、over heat etc.
Cooling method
Air cooling
Noise
<50dB
Protection class
IP20(indoor)、IP65(outdoor)
Width ×depth ×height(mm)
600*500
*1000
800*600
*1800
800*600*2260
Single screen
800*1200*2260 double screen
2400*800*2260 three screen
Weight(kg)
150
400
600
800
1200
1800
 
Three-phase series small wind turbine grid-connected inverter